Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
Honeywell Hot Surface Ignition Control Board, 120 VAC Line, 24 V (18-30 VAC) Low, 5 A at 120 VAC, 60 Hz, 30/60 s Heat On, 60, 90, 120 or 180 s Heat Off, 5 s Cool On, 0 to 60 s Cool Off Time Delay, 0 to 95% Relative Non-Condensing Humidity Rating, -40 to 175 deg F, For Use With: Single Stage Warm Air Furnaces
| Humidity Rating | 0 to 95% Relative Non-Condensing |
| Temperature Rating | -40 to 175 deg F |
| Voltage Rating | 120 VAC Line, 24 V (18 to 30 VAC) Low |
| Amperage Rating | 5 A at 120 VAC |
| Frequency Rating | 60 Hz |
| Time Delay | 30/60 s Heat On, 60, 90, 120 or 180 s Heat Off, 5 s Cool On, 0 to 60 s Cool Off |
| Suitable For Use With | Single Stage Warm Air Furnaces |
- Flame rectification circuit to monitor flame presence
- Monitoring of system pressure switch, high temperature limit and rollout functions
- Appliance operation/safety requirements controlled via microprocessor
- Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat
- Three LED system status, performance and diagnostic indication
- Twinning capability
- Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances


Installation/Instruction Manual