ICM™ DSI Furnace Control Board, 115 VAC, 60 Hz, 1 ph Phase, 30 s (Pre Purge) Time Delay, -40 to 176 deg F, 5-3/4 in L x 6-5/8 in W x 2-1/2 in H
Dimensions | 5-3/4 in L x 6-5/8 in W x 2-1/2 in H |
Frequency Rating | 60 Hz |
Phase | 1 |
Temperature Rating | -40 to 176 deg F Operating |
Voltage Rating | 115 VAC |
Time Delay | 30 sec (Pre Purge) |
- Controls inducer motors, air cleaner (if equipped), humidifier (if equipped), spark igniter and the gas valve
- Micro-processor based precision
- Monitors timing, trial for ignition, flame sensing, lockout, system switches
- 100% lockout safety feature
- Compatible with LP or natural gas
- LED indication for status and fault codes to aid in troubleshooting
- 1 hr lockout